便携式数字光谱仪
--------------------------------------------------------------------------------
DIGITAL FIBER SPECTROMETER
(STDFSM2060)
STDFSM2060 (ScopeTek Digital Fiber SpectroMeter) is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Because of the high stability and high performance, these portable instruments can greatly satisfy the increasing need for scienti?c research, industrial manufacture, online detections and so on.
STDFSM is capable of measuring
Spectral power distribution,
Absorbance, transmission,
re?ection,
Relative irradiance,
Chromaticity coordinates,
Color temperature,
Color rendering index,
Color tolerance,
Color difference,
Color purity,
Main wavelength,
Luminous ?ux,
Luminance,
Irradiance power and
Luminous effciency
.etc of various kinds of samples, light sources and display devices. Besides they can also be utilized to achieve photochromic analysis of
Florescence lamps,
High pressure gas discharge light sources,
Halogen-tungsten lamps, medical light sources,
Semi-conductor lighting devices and
Display devices as CRT, LCD, PDP, ELD, VFD.
STDFSM can offer the optimal solutions for spectral detections. With different system con?gurations and sampling accessories, STDFSM can achieve high spectral resolution up to 0.2nm, stable wide, narrow and line spectrums with different optical interfaces. Furthermore, with the easy-to-use basic operating software and high effcient SDK, end users could easily achieve various kinds of spectral dectection systems to meet their own goals.
Mechanical parameters
Dimensions (mm)
95×68.5×36
Weight (g)
210
Detector speci?cation
Detector
Sony ILX511 2048 Linear CCD array
Detector wavelength response range (nm)
200-1100 (200-850 & 350-1100)
Pixels
2048
Pixel size (μm)
14×200
Pixel well depth (number electrons)
105
SNR
300:1 (full signal)
A/D resolution
12bit
Dark noise (RMS counts)
50
Corrected linearity
99.8%
Sensitivity (photons/count)
400nm : 130; 600nm : 60
Optical bench
Optical system
f/4, asymmetrical crossed Czerny-Turner
Focal length (mm)
45 (input); 70 (output)
Entrance aperture (μm)
5, 10, 15, 20, 50 .etc width slits or ?ber (customizable)
Grating
various kinds of scoring grating or holographic grating with di?erent grating constants and ?are wavelengths (customizable)
Cylindrical lens
optional
Optical ?lter
bandpass or longpass ?lters to eliminate secondary spectrum
Fiber and ?ber connection
NA 0.22, SMA905 (customizable)
Spectroscopic
Wavelength range
depend on optical grating
Optical resolution (nm)
0.2-10 FWHM (depend on grating constant, width of slit and detector model)
SNR
300:1 (full signal)
Wavelength tolerance (nm)
about ±0.2
Dark noise (RMS counts)
50
Integration time
10μs-64s
Dynamic range
2.0×108(system); 1300:1 (single acquisition)
Stray light
<0.05% at 550nm
Electronics
Power consumption
250 mA×5 V DC
Data transfer speed
full spectrum into memory every 5 ms at USB 2.0 (16ms at USB 1.1)
Computer
Operating system
Windows 2003/XP/Vista
Interface
USB 2.0 (480Mbps), compatible with USB 1.1
Pre-de?ned system components
Name
Customizable parts
Remark
Slit
Width (μm)
10, 20, 50, 100 .etc
Grating
Lines per unit (L/mm)
300, 600, 1200, 1800
Working wavelength range(nm)
200-1100 (User de?ned, about 650 range with 600 lines/mm grating)
Fiber
Core diameter (μm)
9, 50, 200, 400, 600 .etc
Working wavelength range(nm)
200-1100
Outer protection layer
Normal or enhanced jacketing
Interface type
SMA 905 (standard) or FC, ST .etc
Detector
Model
Sony ILX511
Cylindrical lens
Optional
Enhance system’s light gathering ability
Optional components
Name
Remark
Light source
Used for wide range spectral measurement or wavelength calibration for example halogen tungsten, xenon or argon light sources
Integration sphere
Used to acquire uniformed light
Re?ection measurement accessory
Components used for re?ection spectrum measurements for example standard re?ection board or specialized clamp
Transmission measurement accessory
Components used for transmission spectrum measurement for example sample holder and various kinds of cuvettes
Packing list
Name
Amount
STDFSM micro ?ber spectrometer
STDFSM2066
Fiber with SMA 905 interface
1
Mini USB data transfer wire
1
CD of Software and SDK
1
System Drawing
Fig 1. System drawing
Detection Result
Fig 2. Detection result of standard low- voltage mercury lamp( 1200L/mm grating and 50um slit)
Fig 3. Detection result of standard low- voltage mercury lamp( 1200L/mm grating and 9um slit)
Fig 4. Detection result of HG-1 mercury argon calibration light source ( 600L/mm grating and 50um slit)
Left:DFSM3666's Right:A world famous brand's
配置清单